Why do VMP vertical multistage centrifugal pumps need to lift the pump shaft when installing the motor?

Q: Why do VMP vertical multistage centrifugal pumps need to lift the pump shaft when installing the motor?




A: VMP vertical multistage centrifugal pump installation requires the tool to lift the whole series of rotor 2mm, tighten the bolt on the clamp coupling, complete the rigid connection between the pump shaft and the motor shaft, which is especially important for customers who only buy the pump head back to install, the result of not lifting is the pump operation is difficult, seriously cause motor burn and bottom impeller damage.